Bank Tube Failures in Bi-drum Boilers

Written by:  • Edited by: Lamar Stonecypher
Updated May 24, 2011

Bank tubes in bi-drum boilers act as raisers and down comers between the two drums. They also carry the load of the bottom drum and its down comer. Failure in these tubes needs to be attended depending upon the type of failure and the location of failure.

Bank tubes are used to connect the upper drum and lower drum in bi-drum boilers. These bank tubes not only act as raisers and down comers between the drums but also carry the weight of the bottom drum and the down comer of the bottom drum. Any failure of these tubes results in damage to the nearby tubes or drum or both, depending on the location of the leak. Attending to these failures require special care and methods.

These joints are mechanically held by the expansion of the tube in the drum holes. The tube deforms to a plastic condition and the drum hole, being in elastic condition, exerts the required sealing force for the joint against the drum operating pressure. It is seen that an expansion resulting in about 7 to 11 % thinning of tube thickness results in a good joint. Normally these joints are more effective for pressures up to 120 kg/cm2. Tube wall thinning can be calculated by knowing the tube ID before and after expansion.

D1 = Tube ID before rolling when the tube OD just touches the drum hole. This is achieved after light rolling and is called touch rolling; not much torque will be required for this. Once the tube OD touches the drum hole ID, the expander torque will increase indicating the tube has touched the drum hole ID.

D2 = Tube ID after rolling

T1 = Tube wall thickness before rolling. Note: Even at touch roll point the thickness of the tube is the same as that before starting touch expansion.

Percentage thinning = 50 x (D2 - D1) ÷ T1

There is also a practice to measure the thickness before and after expansion and calculate the percentage of thinning. However it is my experience and opinion that measuring tube ID is more reliable after expansion. Hence I always prefer to use the diameter method.

Reasons for bank tube failure

  • The main reason for bank tube failure due to expanded joint failure is inadequate expansion. Many times it is very difficult to measure each tube ID for checking the percentage thinning, hence it is a practice to measure a few tubes in every 100 or 200 tubes and fix the expander torque to get the required thinning. This torque is applied to the tubes and is taken for granted that the expansion is achieved. This is true only if proper lubrication is done on the expander rollers so that minimal torque is lot in friction and the thinning is achieved.
  • Expanded joint also fails due to thermal shock created due to large number of start-ups and shut downs in a short span; say 50 start-ups and shutdowns in about ten to twenty days.
  • Internal deposits leading to long-term overheating failures
  • Blockage leading to short term overheating failure
  • Erosion and corrosion of tube surface

Attending to the bank tube failure mainly depends on the type of failure and the intensity of the failure.

  • In case of expanded joint leakage resulting in puncture of the tube, generally it is the practice to plug both ends of the bank tube in top and bottom drum. This is mainly due to the reason many a times it will not be possible to reach this tube location without removing large number of tubes. Plugging tubes should not be adopted if locally there are many tubes to be plugged. This can cause problem in other tubes nearby.
  • Plugging is adapted to other type of failures when approach is not there without removing many bank tubes. No spool piece welding is to be done on bank tubes as this can cause failure in the expanded joint.
  • When the failure reason is established as low expansion carried out, then re-expansion has to be done in all the tubes. It is always better to restrict the thinning of the tube thickness to a maximum of 15 to 18%. Above this you will see that the tube material start flaking and lead to brittle failures.
  • Seal welding of bank tubes is permitted after expansion. All precautions are to be taken during welding not to deviate from the welding procedure as any welding on drum has to be done with the utmost care. It is required to lightly re-roll the seal welded tubes and do not flare the tube end.

Replacing all the bank tubes

There are times when all the bank tubes need changing. The procedure will have to be carried out by an expert group knowing all the implications while carrying out this.

Since the entire bank tubes are to be replaced,

  • The bottom drum has to be properly supported before removing the old bank tubes
  • After removing the bank tubes, each hole in the drums (steam and mud drums) has to be checked for its required dimension and for any damage before replacement of the tubes
  • For enlargement/ovality in the holes, the normal tolerance limit for acceptance is (d+0.032” ) + 0” / - 0.015” ; where ‘d’ is the outside diameter of the bank tube
  • If due to steam or water erosion the hole size is more than the limit, then weld build up has to be carried out to get the required size with suitable preheating and post heating.
  • After getting the required hole size, the insertion and subsequent expansion of the bank tubes have to be carried out in proper sequence
  • If seal welding is carried out with suitable electrode and with required preheating.
  • Do not weld the bank tube directly to the drum without achieving required expansion on the bank tubes, and no strength weld is allowed in this area.

Related Reading

Boiler tube failures are inevitable. There are twenty-two primary reasons for tube failures in a boiler. It is true that being forewarned is being forearmed. Knowledge and good operating and maintenance practice reduce tube failures.

As carbon emission is a major concern today, more super critical pressure units are bound to be preferred due to the increase in plant cycle efficiency. This will make once through type boilers take over from drum type boilers.


Comments

Showing all 10 comments
 
Dr V T Sathyanathan Jun 13, 2011 1:12 PM
Replt to Susanto
Only expansion is the method for expanded joints as the name indicates. If there is a need to go for seal welding e can do so. All care must be taken for seal welding these tubes. Proper preheat temperature and weld parameters have to be adopted.
Regarding go / no-go gauge it is a quick method of determining whether the dimension is within the specified range and not a method of actual measurement. This has to be clearly understood.
susanto Jun 13, 2011 3:37 AM
go/ no go metode
due our project in power plants, we have some problem to fixing water bank tubes with no groove on steam drum, so my question:
1. how to fix the tubes to steam drum holes except by expands metodes
2. how accurate of go/ no go metode to fix this problem
Dr V T Sathyanathan Nov 20, 2010 5:59 AM
Reply to B K Parekh
Generally about 10% of bank tubes can be plugged in VU 40 boiler. This should not be in one location but scattered around.
B K Parekh Nov 20, 2010 4:29 AM
Bank tube
How much percentage of Bank tubes are allowed to plug for Bi drum VU 40 Boilers.
Dr V T Sathyanathan Nov 16, 2010 10:18 AM
Reply to Ramkumar G
Not clear about your question
Dr V T Sathyanathan Nov 16, 2010 10:17 AM
Reply to Saad Alrawi
Such a failure during startup / commissioning of boiler is generally due to blockage.
ramkumar g Oct 29, 2010 4:19 AM
belling angle
how to fix the belling angle for drum and bank tubes
saad alrawi Oct 28, 2010 3:11 PM
fish mouth failer
in my company we have a water tube boilers have energy of 80 tons/h of s.h steam 43 bar
we are re-tubing all the tubes (wall tubes & bank tube&s.h&economizer )except the drums we used the old drums.
we test hydraulic test by 63 bar used boiling water and the result is very good.
after we end the insulation works we running the boiler to 5 hours in energy of 80 t/h then the first tube in left wall tube in the top of burners is failed by fish mouth frailer.od of tube is 76.1mm and the thickness is 5 mm just for this tube
the other tube have thick. of 3 mm and material is st.45.8 for all tube
aim ask for the causes for this one of failed.
why just this tube is failed and he has a larger thickness.
thank you very much
Dr V T Sathyanathan Sep 23, 2010 8:16 PM
Reply to Vinayak Hegde
Plugging bank tubes is a normal procedure, but if this has happened before light-up then the tube ends can be plugged by temporary hydrotest plug and check if any other tube has leakage. After this if the tubes can be easily changed it is better to replace than permanent plugging. This again depends on the reserve available and other factors.
Vinayak Hegde Sep 18, 2010 9:52 AM
bank tube
We have one no bank tube pin hole leakage during hydrotest of newly erected boiler yet to be fired.The supplier says he will plug at both the ends. But by removing the 4 tubes the entire damaged bank tube can be replaced. the pressure of the boier is 20Kg/cm2. Please suggest whether to go for plugging the bank tube or replace the damaged bank tube in view of the new boiler yet to be fired.
 