Effect of Mill Outlet Temperature on Boiler Performance

Written by:  • Edited by: Lamar Stonecypher
Updated Aug 15, 2010

The mill outlet temperature directly impacts the dry gas loss in boiler, which is a major loss and in turn a loss of boiler performance and efficiency. Two major parameters which decide the mill capacity and performance are the hardness of the coal and the total moisture level in the coal.

Pulverizing mills in boiler plants play a major role in preparing the coal for firing in a boiler. Coal, being a heterogeneous fuel, varies in its properties; the variation depends on many factors like type of origin of coal, formation, etc. Two major parameters which decide the mill capacity and performance are the hardness of the coal and the total moisture level in coal. The hardness of coal decides the amount of load required to grind and recirculate within the mill. The moisture level decides the amount of hot air required and has a direct effect on the milling capacity in many cases. To make sure the fuel is prepared to an acceptable level for combustion, the mill outlet parameters of coal is maintained within a specified range. The fineness of coal which gives the measure of pulverizing is maintained to a level of 75% though 200 mesh and less than 1 to 2% over 50 mesh. The mill outlet temperature of coal-air mixture is maintained between 65 to 90 degree centigrade in the case of low and medium volatile coal. In the case of high volatile coal, while the lower limit generally remains as 65 degree centigrade, the upper limit is restricted to a lower level depending on percentage of volatile content in coal. This is mainly done to avoid mill fire and mill explosion.

While all these are regarding the mill performance, the coal fineness and mill out let temperature also affect the boiler performance. The coal fineness has an effect on the combustion performance like the bottom ash percentage combustibles when the plus 50 mesh percentage goes up. It has been very well established that in the case of tangential firing system, the percentage of combustibles has a direct bearing on the plus 50 mesh percentage. However the changes in the case of 200 mesh passing though has only a very minor or no effect on the percentage of combustibles in fly ash. This is mainly because of the fact that the residence time available in a large capacity boiler and the type of burning system will be able to address this in a wide range. It is found that in tangential firing system the reduction in fineness even to a level of 65 percent through 200 mesh did not affect the combustibles. But the main change was in bottom ash combustibles due to increase in 50 mesh retention percentage. It is to be noted that all this results in combustibles loss in boiler and the magnitude is low, however it makes a difference when we talk about finer aspects of boiler performance levels.

The mill outlet temperature has a major impact on the boiler performance levels. The mill outlet temperature directly impacts the dry gas loss in boiler which is a major loss. This depends on the moisture level in coal, the higher the moisture level the quantity of hot air required in mill for the same mill load is higher. In fact in cases where moisture levels are very high the tempering air required will be zero. But in the case of moisture levels being on the lower side the quantity of tempering air keeps increasing. It is at this time the boiler operating engineers will have to decide to go to higher level of mill outlet temperature to reduce the tempering air quantity. The tempering air bypasses the air pre-heaters in boiler thus reducing the heat recovery from the flue gases leaving the boiler. This increases the boiler exit gas temperature which in turn increases the dry gas loss in boiler.


Comments

Showing all 5 comments
 
Dr V T Sathyanathan Feb 16, 2011 3:26 AM
Reply to B R Murari
Thank you, I shall soon try to write on both the topics.
B R Murari Feb 9, 2011 2:15 AM
Coal mill explosion
I have read most of your posts.These are really helpful for ppl working in thermal power station.Will you pls post something regarding safe coal mill operation & pls tell how to avoid explosion in coal mill.
Thanking you.
Dr V T Sathyanathan Sep 4, 2010 9:10 AM
Answer to Prabhakar P Singh
PRABHAKAR.P.SINGH
Subject: AIR HEATER

what is the right gap / clearance of top and bottom sealing in cold condition.

The gap can be a varying number by different manufacturers and the type of gap control used. The gap must be in such a way that at all operating conditions there should not be any mechanical rubbing and must ensure minimum leakage. Based on these principles the supplier of air pre-heater would recommend a particular gap to be set please follow this.
Dr V T Sathyanathan Jul 20, 2010 12:03 PM
Reply to Govind Khaddar
The coal analysis show a moister level of only 10% and the VM is 51. This coal will have a problem of mill fires even at 60 to 65 degree C. I would suggest the mill out temperature can be lowered to 60 degree C and then slowly taken down to may be as low as 55 degree C. but carefully watching the furnace pressure variation. If no disturbance is seen setting in then it can be left at that. My guess will be you should be able to stabilize at 58 degree C without difficulty. Best wishes.
GOVIND KHADDAR Jul 19, 2010 3:57 AM
mill outlet temperature
As suggested by Dr. V T Satyanathan in the article the mill outlet temperature of coal air mixture may be maintained between 65 to 90 deg centigrade in case of low and medium VM Coal. However, in case of High VM (40 to 50) coal it appears to be very difficult to maintain even 62 to 65 deg centigrade, as it is likely to catch fire even in practically unavoidable overlooks during operation of the plant.

We seek guidance to arrive at an optimum mill outlet temperature for coal with 10%moisture, 3.8% Ash, VM 51% and GCB 5233 K Cal /kg. which we are using in a 600 MW front end rear wall fired Boiler.

Regards,

Govind Khaddar
 
blog comments powered by Disqus