How does a Gas Turbine Power Plant Work? The Auxiliary Systems.

Written by:  • Edited by: Lamar Stonecypher
Updated Nov 18, 2009
• Related Guides: Fuel | Exhaust Systems

Gas Turbines are one of the most efficient equipment for converting fuel energy to mechanical energy. How does a Gas Turbine work? What are the auxiliary systems for the Gas Turbine? This article explains in simple terms the working of the Auxiliary Systems in the Gas Turbine Power Plant.

The three main sections of a Gas Turbine are the Compressor, Combustor and Turbine. The gas turbine power plant has to work continuously for long period of time without output and performance decline. Apart from the main sections there are other important Auxiliaries systems which are required for operating a Gas Turbine Power Plant on a long term basis.

Air Intake System

Air Intake System provides clean air into the compressor. During continuous operation the impurities and dust in the air deposits on the compressor blades. This reduces the efficiency and output of the plant . The Air Filter in the Air Intake system prevents this.

A blade cleaning system comprising of a high pressure pump provides on line cleaning facility for the compressor blades.

The flow of the large amount of air into the compressor creates high noise levels. A Silencer in the intake duct reduces the noise to acceptable levels.

Exhaust System

Exhaust system discharges the hot gases to a level which is safe for the people and the environment. The exhaust gas that leaves the turbine is around 550 °C. This includes an outlet stack high enough for the safe discharge of the gases.

Silencer in the outlet stack reduces the noise to acceptable levels.

In Combined Cycle power plants the exhaust system has a ‘diverter damper’ to change the flow of gases to the Heat Recovery Boilers instead of the outlet stack.

Starting System

Starting system provides the initial momentum for the Gas Turbine to reach the operating speed. This is similar to the starter motor of your car. The gas turbine in a power plant runs at 3000 RPM (for the 50 Hz grid - 3600 RPM for the 60 Hz grid). During starting the speed has to reach at least 60 % for the turbine to work on its on inertia. The simple method is to have a starter motor with a torque converter to bring the heavy mass of the turbine to the required speed. For large turbines this means a big capacity motor. The latest trend is to use the generator itself as the starter motor with suitable electrics. In situations where there is no other start up power available, like a ship or an off-shore platform or a remote location, a small diesel or gas engine is used.

Fuel System

The Fuel system prepares a clean fuel for burning in the combustor. Gas Turbines normally burn Natural gas but can also fire diesel or distillate fuels. Many Gas Turbines have dual firing capabilities.

A burner system and ignition system with the necessary safety interlocks are the most important items. A control valve regulates the amount of fuel burned . A filter prevents entry of any particles that may clog the burners. Natural gas directly from the wells is scrubbed and cleaned prior to admission into the turbine. External heaters heat the gas for better combustion.

For liquid fuels high pressure pumps pump fuel to the pressure required for fine atomisation of the fuel for burning.

(untitled)

These are the main Aiuxiliary systems in a Gas Turbine Power Plant. Many other systems and subsystems also form part of the complex system required for the operation of the Gas Turbine Power Plant.


Comments

Showing all 67 comments
 
Rodz Gertos Feb 5, 2012 5:25 PM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
hello.. hmm.. may i ask if from what price do gas turbine engines ranges from?,. let's say from a 4MW sgt above...its for our project at school. <br>many thanks!!:)
vouchers Nov 20, 2011 4:55 PM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
Natural gasoline has an octane rating of about 30 to 50, sufficient for the low-compression engines of the early 20th century. By 1930, improved engines and higher compression ratios required higher-octane, refined gasolines to produce power without knockingor detonation.
rashid Oct 11, 2011 3:32 AM
Excitation system
hi everybody
i'm student on engineering college on leve-4,i'm prepare for project of thermal cycle (Gas turbine)on excitation system.i' need help and support.
Thanks.
Rashid
cruz Aug 12, 2011 12:49 AM
have an idea but not in the field
need to know best method to design a floating LNG power plant which can produce major MW(20,000), and a reliable way to supply it.
Anonymous Jun 24, 2011 4:27 AM
turbine installation and maintenance manual.
Dear John,
i am looking towards being hired as a field engineer,for turbine installations and maintenance in a power station.i have little knowledge about gas turbines and compressors and other rotary equipment,having had my industrial training in a Refinery.Is there any where i can fine some information or a manual on gas turbine installation and maintenance?.
kola May 9, 2011 4:39 PM
metal matrix composite
if MMC is used to make gas turbine blades, what are it benefits and drawbacks?
kola May 9, 2011 4:37 PM
composites
I'm currently writing a coursework on composite materials used for making turbine blades. I'm certain about CMC but not sure of MMC.
johnzactruba Apr 1, 2011 11:15 AM
reply shaan
Coal fired thermal power plants use the modified Rankine cycle.
shaan Apr 1, 2011 8:18 AM
having intrview cal
Dear Mr. John
i want to know which cycle is used in coal fire boilers
thirupathi rao Feb 8, 2011 4:04 AM
cal of efficiency
and also provide the information regarding the efficincy(formulas) calculation of gas turbine(i hav practical data)

thanks for valuable information which ur provded for last question
thirupathi rao Feb 8, 2011 4:00 AM
over all equipment performance
hi johnzactruba, i know mtbf and mttr and availity and reliability (all reliability metrics)now the prob is how i can calculate over all eqiupment effectiveness of gas turbine.
johnzactruba Feb 5, 2011 8:41 PM
reply tirupathi
The following link that gives the details of the gas turbine systems used for reliabilty analysis.
http://ehakem.com/index.php/IJoT/article/viewFile/235/217
sai sandeep kodimala Feb 3, 2011 3:36 AM
Reply to can we use Gas turbine for 13MW power outpu
It is possible option and it is widely proven technology in India.
For your reference

A Power plant in Tamil Nadu with similar capacity and configuration as per requirement is operating

Company :OPG Power Plant, Probably this one using for captive purpose

A Gas engines with Heat Recovery unit possible option
Probably Siemens are manufactures for the capacity requirements
tirupathi Feb 3, 2011 2:08 AM
gas turbines
again me here,other wise can u suggest some best sites to get the relevent data of gas tubines to perform the reliability(performance analysis)
tirupathi Feb 3, 2011 2:01 AM
gas turbines
to perform the reliability analysis of entire gas turbine we suppose to know each and evry component in the gas turbine right,can u please send me the documents regarding the entire gas turbine system,at present am working in that area.it is difficult to get that data of each and evry component data by search can pls help me.
Ejaz ahmad Feb 1, 2011 6:33 AM
gas turbine...
what are the types of gas turbines use in power plant?
johnzactruba Dec 17, 2010 10:31 PM
reply sitaram
Gear boxes will reduce the rpm from the GT value to the required value.
sitaram Dec 15, 2010 11:11 PM
how to reduse the speed by using multi shaft
by using muti shaft tyrbine how we can reduse the speed 6000rpm to 300 rpm ?
thanku.
M Asad Ullah Dec 5, 2010 8:43 AM
Reference Point Of Gas Turbuine
Dear Mr. jhon
i want to know that why the Reference of a Gas Turbine decrease when we Convert it on DIESAl
Thnks i m waiting for ur ans.
M Asad Ullah
johnzactruba Nov 16, 2010 7:37 PM
reply ravi
1. You should know the GCV of the fuel ~ 42000 kJ/kg
2. Calculate the heat rate HR= 3600/efficiency = 3600/0.55 =6545 kJ/kw.hr
3 Fuel consumed QF
=HR/GCV =6545/42000 = 0.156 kg/kw.hr
4. Total fuel
= MW x 1000 x QF = 50000 * 0.156
=7800 kg /hr
ravi Nov 16, 2010 2:13 AM
liquid fuel calculation
How can i find the amount of fuel(fiq,ex-heavy fuel oil) used for 50MW ,and 55% of Efficency
johnzactruba Nov 13, 2010 7:17 AM
reply R.Adinarayanan
- low capacity gas turbines are available even upto 1 MW. Waste heat boilers can also be connected to the exhaust. It is only a matter of cost economics.
-In Coal producing countries the cheapest alternative is Col based steam power plants. But with tighter CO2 emisioin regulations this will change.
- basic equation is
kw=sqrt 3 x V x I x power factor.
Vx I is the kva
kw=kva x sqrt 3 x power factor
R.Adinarayanan Nov 12, 2010 6:12 AM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
how do we convert these power units in to MW
6900kvA@4160V ,
8200kvA@480V
Can you provide with calcualtion
R.Adinarayanan Nov 12, 2010 6:08 AM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
which is the cheapest going for gas turbines or going by steam turbines in USA? Thanks
Adinarayanan Nov 12, 2010 5:57 AM
Can we use Gas turbine for 13MW power output?
Dear Mr. jhon

Is it possible to have Gas turbines (or) gas engines for 13 MW power out put power & also at the exhaust of turbine can we use any waste heat recovery boiler?
boris tezak Nov 2, 2010 3:45 PM
gas turbine
hello,my name is boris. I have done many blade repairs and other repairs on steam turbines (Parsons nad GE), Now I have been offered a job to install a new gas turbine. Where can I find some info on the istlation methods. I am a millwright by trade and have installed many large machines before.
Oliver Williams Sep 29, 2010 6:35 PM
thanks John
Thanks John. Appreciate your response.
Regards,
OW
johnzactruba Sep 29, 2010 6:16 PM
reply oliver
37.5 % efficiency is 3600/.375 = 9600 kJ/Kw.hr
For 47 MW is 47*1000 kw per hour which means
47000*9600 kj/hr of gas is required.
If the CV of gas is XXX kj/M^3 then
47000*9600 / XXX M^3 of gas is required per hour.
oliver Sep 29, 2010 6:37 AM
Gas Requirements
Hi,

how do I determine the amount of gas required to operate a gas tubine? Is it based on the output and efficiency? For example if I have a turbine of 47MW with 37.5% efficiency, do I covert the volume for 47MW into gas then add 62.5% on top of that? Thanks.
johnzactruba Sep 15, 2010 7:06 PM
reply anjum
The gas turbine and generator has big mass. The gas pressure alone will not be able to even rotate it.
You can calculate the output by knowing the efficiency ( around 35 % ) whicsh is 3600/.35 = 10286 kj/kwh. If you know the heating value of gas say 40000 kj/NM3 then gas qty is 10286/40000 = 0.257 NM3/kwh.
anjum Sep 14, 2010 3:03 PM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
hi.my question is for any out put rating gas turbine, what is the approx ratio of natural gas consumed or is there any turbine system which could produce electric energy with passed through gas pressure only without consuming gas quantity.if yes how.thanks.
johnzactruba Aug 11, 2010 9:45 AM
reply Hadi
Hope this is only one time affair due to a manufacturing defect in the blade.
Hadi Aug 10, 2010 3:06 PM
Reply john
this happen after 1 year of operation, no high vibrations occur and yes it is the only incident
johnzactruba Aug 9, 2010 6:36 PM
reply Hadi
Failure at the root is normally because of fatigue stress. The blade is subject is some kind of aerodynamic stress,
Could be a deficiency in the blade design, so that after a certain no. of hours the fatigue stress cracks occur leading to failure.
Is this only a single incident ? After how many hours of operation has this taken place ? was there any high vibration ?
Hadi Aug 8, 2010 2:25 PM
ACC fans
Dear john,
today one of the ACC fans is break down, one of the blade is broke from the joints, the bolt is make a failure
this causes the blade to break from the root and fall down on the ground, what is the possibilites for failure like this? is it related to operational hours or maybe the bolt is tightened more than limited torque?
S.Narenra Giri Jun 1, 2010 11:02 AM
Gas Turbine air sealing
Sir, Please expalin the air seal system in gas turbine and power turbine , also appreciate your goodnes to brief about hydraulic oil system.
Thanking you with kind regards
S.Narendra Giri
UAE
johnzactruba May 7, 2010 9:21 AM
reply Awaneesh
Generators run at 3000 rpm ( for 50 Hz) or 3600 rpm (for 60 Hz). Some Gas turbines especially aeroderivitives run at 6000 rpm .This is reduced to 3000 rpm by speed reducers. Hence it is called multi safts..
Awaneesh May 6, 2010 9:57 PM
Difference between single shaft and double shaft Gas turbines
I wish to know the difference between Single shaft and double shaft Gas turbines, the benefits of one over the other. Also, stating the purpose of using 2 shafts..
Also, I wish to know the benefits of using axial compressors in gas turbines instead of centrifugal or any other type of compressors..
Awaneesh May 6, 2010 9:52 PM
Difference of Mark V and Mark VI Control system for Gas Turbines
I wish to know the difference between markV and mark VI control system for operation of Gas Turbine, in terms of Hardware , date transmission, redundancy and software. Can anybody please provide the information..
Barkat Apr 30, 2010 2:36 PM
Power plant outages
What is the meaning of Equivalent planned/Unplanned derated hours and how we will calculate.
Barkat Apr 30, 2010 2:29 PM
Fesability report of 11KV and 132KV System and Comparision
Technical aspect of 11KV and 132KV with degree of comparison affect on System
Barkat Apr 30, 2010 2:24 PM
Gas Engine Efficiency(GEJB620 Gas Engine)
A gas line distribution for Eight engine but their inlet gas temperature on three engines are more 4 to 7c to others, and also running gas flow of these three engines are more than others which directly impact on heat rate and efficiency.I want to know the reason/facts why the 3 engines inlet temperatures are more.
solo musa Apr 27, 2010 6:22 PM
hydrogen gas powering a turbine
Hello,
I would like to know if hydrogen gas can be used to power a gas turbine? if yes, do you know what the combustion ratio of hydrogen gas to air might be for a good combustion? thanks a lot.
Solo musa ( student)
sai sandeep kodimala Apr 15, 2010 4:53 AM
hai
hai balasubramanian this is Sandeep , would u like to know gas units valuthure village, ramanthapuram distrcit Tamil Nadu,

Right Now nearly 3 Gas Power plants operating in the valuthoor with Different technologies

1) 52.8 MW Natural Gas Power Plant based Gas
Turbine CCCP-Penna Electricity Limited
2) 75 MW Gas Engines Based Power Plant(CCCP) _ Arkay Energy Limited

Other Plant Working under Control of TNEB
sbalasubramanian Apr 15, 2010 1:58 AM
hi,iam bala
may know gas power plant located in valuthoor
sbalasubramanian Apr 15, 2010 1:57 AM
hi,i am bala
may know gas power plant is located in valuthoor
devendra Apr 5, 2010 8:00 AM
gas turbines and gas power plant
comparison with steam , diesel and hydel power plant, performance of gas turbine power plant part load efficiency, air flow rate
Sai Sandeep Kodimala Mar 31, 2010 3:49 AM
Dearting Factor
Thanks a lot for the reply
johnzactruba Mar 30, 2010 7:39 PM
reply barkat sandeep
Derating has two consider 2 factors.
1. Change in actual density from iso conditions. This takes care of altitude, RH % and abient temperature changes.
Power_act= Power_iso x density_iso / density_act
In practice there may be slight changes because of efficiency and automatic corrections . This can be got only if we refer to the manufacturers correction curves.
2. Account for Entry and exit losses.
Roughly it is 1.5% power output decrease and 0.5 % increase in Heat rate for 10 mbar increase in inlet pressure.
0.5 % power output decrease and 0.5 % increase in Heat rate for 10 mbar increase in exit pressure.
This also has to be correlated with manufacturers correction curves and is specific to different capacities and types.
Barkat Mar 30, 2010 2:35 PM
Derating factor
Pl give me detail about derating factor and how we will calculate depands onwhat factor
Kodiamla sai sandeep Mar 24, 2010 8:22 AM
De-rating factor
Yes sir, I would like know about de-rating factor, how it is effects on the performance on the Gas turbine during the life time. Any procedures are to estimate De-rating factor and remedies to overcome from this problem
johnzactruba Mar 19, 2010 8:12 PM
reply sai sandeep kodimala
Did you mean de-rating factor ?
sai sandeep kodimala Mar 19, 2010 7:50 AM
Dearting Factor
Nice Article to understand about principle & working procedure about Gas turbine
Sir let me now, how the Dearting Factor is affected on the performance of GTG and how it is estimated with respected to working hours. Any remedies to control the dearting factor. I was very thankful to them if any one is provide the information to above problem and let me know any problem are associated with GTG other then Dearting
Ashwani Kumar Feb 25, 2010 2:56 AM
Reheat in Gas Turbine..
Give me explanation about reheat and regeneration process in gass turbine with diagrams....
Farhad Rafiq Feb 6, 2010 11:18 AM
Gas Turbine Power Plant
very simple and easy to learn
kyaw Jan 21, 2010 12:25 PM
please, help me.
i wants to know about menufacturing of electric(20kw-50kw) by biogas ,and how it produce? for small industry with 50 to 100 peoples. and also low cost,easy way .
DASARI Dec 17, 2009 8:27 AM
simple to understand
good for intial learners
johnzactruba Dec 8, 2009 5:11 PM
reply to allen ong
Apart from the safety valves and rupture discs provided in the steam line , from the steam field to the turbine , there is one major device . This steam release valve , which lets out the steam to atmosphere in case sudden trip on the turbine side. This is a quick acting control valve. The special thing about this is the steam is released through a rock muffler to reduce the sound.
Allen Ong Dec 8, 2009 4:39 AM
Geothermal Power Plant: List of Protective Devices and its Functions
Can someone name/describe/function of protective devices in a geothermal power plant
karthik Nov 17, 2009 2:22 AM
gas power plant
Good and easy to understand..
Waman R Satpute Nov 7, 2009 6:54 AM
Gas Turbine O & M services
We are an O & M company operating Gas Turbines of 5mw. We would like to know from your experience about following, 1. What we can expect a availability of Gas Turbine for one year operation? 2. What should be maintenance htrs required per year for Gas Turbine of %mw rating? 3 What are the normal maintenance points you will advise us? Routine and schedule 4. We understand that efficiency of Gas Turbine reduces as the running hrs and Out put gets lower as the years pass. Please give your opinion.? 5. Whether 98% load and 98% availabilty is acievable on Gas Turbines? Since Unit generation is the most important part of O & M services. 6 What could be generation O & M ( Without Fuel and Lubricating )cost in$ per unit if one is using Natural gas.
devu vs Sep 17, 2009 12:50 PM
How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
nice explanation..easy to understand..:)
vineet srivastav Sep 15, 2009 2:31 PM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
nice explanation.its written in very simple language,so can be understood by everyone..
G.veeresh Aug 25, 2009 3:34 AM
RE: How does a Gas Turbine Power Plant Work? The Auxiliary Systems.
simple and moderate
G.veeresh Aug 25, 2009 3:33 AM
automobiles
crazy and moderate description
G.veeresh Aug 25, 2009 3:32 AM
automobiles
nice and buatiful knowledge on these
sadanandan Jul 30, 2009 3:32 PM
simple and good
simple and moderate description
good
 
blog comments powered by Disqus