Learn about "Capacitor Start - Induction Run" Motors

Written by:  • Edited by: KennethSleight
Published Aug 7, 2009

The starter winding has a capacitor incorporated which makes the single-phase motor a self-starting one. Read here to know about the different types of widely used capacitor-motors

Introduction

We know that the single-phase induction motor can be made self-starting in numerous ways. One such most used method was the Split Phase motors which we discussed in my last article. In this article, we will discuss about the Capacitor Start Induction Run Motors.

capacitor start motor circuit
click to enlarge

Capacitor-Start Induction-Run Motors

We know about the activity of a capacitor in a pure A.C. Circuit. When a capacitor is so introduced, the voltage lags the current by some phase angle. In these motors, the necessary phase difference between the Is and Im is obtained by introducing a capacitor in series with the starter winding. The capacitor used in these motors are of electrolytic type and usually visible as it is mounted outside the motor as a separate unit.

Capacitor start circuit
click to enlarge
During starting, as the capacitor is connected in series with the starter winding, the current through the starter winding Is leads the voltage V, which is applied across the circuit. But the current through the main winding Im, still lags the applied voltage V across the circuit. Thus more the difference between the Is and Im, better the resulting rotating magnetic field.
Externally mounted capacitor
click to enlarge
When the motor reaches about 75% of the full load speed, the centrifugal switch S opens and thus disconnecting the starter winding and the capacitor from the main winding. It is important to point out from the phasor diagram that the phase difference between Im and Is is almost 80 degrees as against 30 degrees in a split-phase induction motor. Thus a capacitor-start induction-run motor produces a better rotating magnetic field than the split-phase motors. It is evident from the phasor diagram that the current through the starter winding Is leads the voltage V by a small angle and the current through the main winding Im lags the applied voltage. It is to be appreciated that the resultant current I, is small and is almost in phase with the applied voltage V.
Phasor Diagram
click to enlarge
As discussed earlier in my last article on split-phase motors, the torque developed by a split-phase induction motor is directly proportional to the sine of the angle between Is and Im. Also the angle is 30 degrees in case of split-phase motors. But incase of capacitor-start induction-run motors, the angle between Is and Im is 80 degrees. It is then obvious that the increase in the angle (from 30 degrees to 80 degrees) alone increases the starting torque to nearly twice the value developed by a standard split-phase induction motor. The speed-torque characteristics curve is exhibiting the starting and running torques of a capacitor-start induction-run motor.
Torque-Speed characteristics
click to enlarge

Types of Motors

There are different types of Capacitor-start motors designed and used in various fields. They are as follows:

  1. Single-voltage, externally reversible type,
  2. Single-voltage, non-reversible type,
  3. Single-voltage reversible and with thermostat type,
  4. Single-voltage, non-reversible with magnetic switch type,
  5. Two-voltage, non-reversible type,
  6. Two-voltage, reversible type,
  7. Single-voltage, three-lead reversible type,
  8. Single-voltage, instantly-reversible type,
  9. Two speed type, and
  10. Two-speed with two-capacitor type.

These motors can be used for various purposes depending upon the need of the user. The starting, speed/torque characteristics of each of the above motors can be analyzed before employing them in work.

torque-speed curves of single-phase induction motors
click to enlarge
In my next article, let us discuss about the shaded-pole single-phase motors.

Image Credits:

www.tpub.com

www.allaboutcircuits.com

A/C-D/C Machines by A.K & B.L. Theraja.


Comments

Showing all 69 comments
 
Peter Chan Feb 4, 2012 1:08 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
I currently work at EMERSON PROCESS MANAGEMENT in the actuator / valve division. I just recently encounter an issue with 115 Vac (1/6 HP) single phase capacitor-start (70mfd) electric motors. Here's the issue: when reversing the motor direction in less than 2 seconds, the motor would still drive to the same direction. This is not always the case but it happens occasionally. Any recommendation will be helpful.<br>
Memosalis Jan 15, 2012 10:53 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
Diagrams are great,thanks!
Subramaniabharathi Dec 2, 2011 2:25 PM
RE: Learn about "Capacitor Start - Induction Run" Motors
subject matter is well presented.
Subramaniabharathi Dec 2, 2011 2:22 PM
RE: Learn about "Capacitor Start - Induction Run" Motors
sir,<br> subject matter is very simple and easy to understand.i need winding diagrams and winding connection diagrams of single phase and 3-phase motors.
Andelotus Dec 2, 2011 11:20 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
A single phase capacitor start and capacitor run electric motor fails to start when the rotor is in one particular position. What could be the reasons and the remedies for the same?<br>-D. Anilan
Rafael A Saavedra Dec 1, 2011 4:01 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
Should the starting capacitor be higher than the running capacitor?   How I can calculate the mf for a motor?
Akhila Nov 30, 2011 3:15 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
we make make it self starting by using capacitor which gives phase shift<br>
Zaid9211 Nov 21, 2011 4:23 PM
RE: Learn about "Capacitor Start - Induction Run" Motors
HABIB UR REHMAN<br>Dr Sir <br>mai ne ak motor winding ke hay 2hp ke singal phase ke lyken wo baghir load k 6amp late hay laken load pa nahi chalte connection be seres  ke hay paralal ke be ke te mugar kamyab na hosaka plz koi hal bata day <br>shokria
ssubramaniabharathi Sep 25, 2011 1:37 PM
RE: Learn about "Capacitor Start - Induction Run" Motors
should i insert coils anti-clock wise or clock wise?
Rafael A. Saavedra Jul 12, 2011 9:57 PM
starting and runnin capacitor
Should the starting capacitor be higer than the running capacitor?
Juan Alberto Rojas Jun 21, 2011 3:50 PM
tamaño y valores
me gustaría saber si existe una tabla con los valores de potencia de acuerdo al tamaño del rotor y de ser así recibirla , gracias un saludo
Juan Alberto Rojas Jun 21, 2011 11:37 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
buenas me gustaría de ser posible recibir el conexionado del producto de 1.5 kw con 11.2 Amp , con el valor exacto de los capacitores ? desde ya muchas gracias y muy buena la pagina
Ron Natali May 22, 2011 2:44 PM
3450 RPM Cap Start motor
I have a 3450 capacitor start pool motor that will not come up to speed to cut out the centrifugal start switch. The motor is only 10 months old. The motor starts, runs for about 15 seconds and then trips the internal breaker. It has 2 caps - 227uf, 110 volt and 20 uf, 370 volt caps. I checked the caps with an analog VOM and it shows teh caps are not shorted and the analog meter shows the caps charging. Any ideas? Thanks, Ron
vaibhav pawar Apr 5, 2011 6:44 AM
about induction motor
How the capacitor start induction motor used in electric fan?
cherono caroline Mar 18, 2011 5:14 AM
shaded pole motor
why do we use copper wire in one side of the winding
Venkatesh Mannari Mar 18, 2011 1:03 AM
Solid state relay
2CR relays
Venkatesh Mannari Mar 18, 2011 1:02 AM
Solid state relay for single phase motor
The cumbersome construction of centrifugal switch design has over come with the use of 2CR relays. How this is cost effective? & where is the source for 2CR Relays?

Regards

Venkatesh Mannari
azhar shah Feb 28, 2011 12:09 AM
single phase motor winding
how can we wind a motor and how many things required for motor winding, how we can use warnish and what is a purpose of warnish.
salman Feb 24, 2011 1:53 AM
motor
please tell me why i am use capacitor in single phase motor.
Ian Story Feb 15, 2011 11:07 PM
Capacitor size
I posted a request about capacitor size on 2oth Jan 2011. When will it be answered?

Thanks.
jaimin r patel Feb 14, 2011 5:20 AM
a.c. motors
dear sir,
please tell me why i am use capacitor in single phase motor.
Boldbaatar Feb 8, 2011 8:36 AM
May I replace capacitor
Hi
May I replace capacitor 5mF 450vAC instead of 3mF 450vAC for draing motor of washing machin?
please replay
uttam Feb 7, 2011 4:51 AM
1-PH, Induction motor in heavy duty exhaust fan
i want to know that what are the major reasons for burning of winding. does capacitor plays heavy role in burning of induction motor. motor is capacitor start & capacitor run motor.
virendra singh Feb 5, 2011 2:07 PM
fan capacitor
why use capacitor in fan motor
virendra singh Feb 5, 2011 2:04 PM
capacitor value calculation
if any capacitor write 104,103 how can calculate in micro farad
virendra singh Feb 5, 2011 1:59 PM
circuit degine
main use of electronics circuit
Ian Story Jan 20, 2011 9:52 PM
Capacitor size
I am having trouble finding a 8uF 300 V. A. C capacitor. Can get a 10uF 375 V.A.C
Will that do the same job?
Umesh Jan 18, 2011 11:03 AM
capacitor
Dear Sir,
I want to know that, how a capacitor mfd selected for a particular motor. Suppose, I want to start a 0.5 hp motor with capacitor, then what will be the mfd off the capacitor for that motor( pls give me the formula)
Badola
badola Jan 18, 2011 10:52 AM
capacitor
sir
if i have 0.5 hp motor with out capacitor, how can i select mfd of the capacitor for that motor (pls give formula)
JOHN RODRIGUEZ Dec 28, 2010 7:31 PM
The speed of induction motor
The speed of an induction motor depends on:
A. Voltage and current.
B.Physical size of the motor
C.Cycles (Hz) and number of field poles.
D. Capacitor size.
JOHN RODRIGUEZ Dec 28, 2010 7:23 PM
refigeration cycle
at what part of the refigeration cycle is the motor current the highest
A. at the instant of starting.
B.at the time that the condenser pressure
is the highest ?
C. at the time that the low-side pressure
is highest
D. at the time that the low-side pressure
is lowest.
E. no difference ; same at all times
Vishnusankar Ramakrishnan Dec 20, 2010 10:25 AM
3 phase induction motor
In star connected motor, the existing star connection is A2,B2,C2. we change the star point A1,B1,C1.when star point changes the motor direction of rotation is changes?.
ajit maskar Dec 16, 2010 5:18 AM
magnetic field
i want to calculate magnetic field in single phase A.C. motor
jojo Nov 26, 2010 11:07 PM
capacitor
how the capacitor works in starting the motor,?
split type and capacitor type is identical except for the capacitor,,
what is the charactristic of capacitor with respect to motor?
ishwar Nov 19, 2010 10:08 AM
capacitor voltage
Sir, why is the capacitor voltage greater than that of the main supply voltage.Thanks
ishwar Nov 19, 2010 10:02 AM
capacitor and horsepower
How do I calculate for capacitance of a cap.start-run motor.
pravin Oct 28, 2010 9:29 PM
hi
sir can u give me detailed information about coconut scrapper as soon as possible?we are using single phase capacitor start motor. sir give all the possible information
karthick Oct 21, 2010 11:41 AM
requesting help
hi sir ,
i want to know the basic in electrical and i dont no where to start can u pls help me
sriram balu Oct 8, 2010 8:04 AM
Selvam: capacitor starter
Selvam,

as you know, in any ac circuit, when a capacitor is added, the current the voltage by some angle (power factor). Thus the current is split in two circuits. this makes the phase difference and thus induces a torque.
sriram balu Oct 8, 2010 8:01 AM
Aura Liesveld
Since the shaft of the 1st motor is driving the shaft of 2nd one (generator), you have to either use it as a rotating field and stationary armature. I.e Excitation is through the rotating shaft and thus as the excitation produces a rotating magnetic field, the stationary conductors are cut and thus emf induced. This can be tapped out from the stator terminals and thus motor can be made as generator.
Aura Liesveld Oct 6, 2010 3:23 PM
Proving a theory:
Sir: I am trying to prove that a motor is a generator in reverse. I am using 2 AC motors. The shaft of the first motor connected to the shaft of the second one. Expecting the second motor to operate as a generator. But I have not been successful to make the second motor to operate as an AC generator. Perhaps you can give me a hand. What am I missing?
Thanks in advance, Aura Liesveld.
Abu Abdallah Sep 28, 2010 12:59 PM
Capacitor start capacitor run induction motor
can u please give me more detail explanation of Capacitor start capacitor run induction motor
Yifrashoa Argaw Sep 13, 2010 3:53 AM
Capacitor run motors
I admire your explanation on the subject
pitambar patro Sep 4, 2010 4:28 PM
Single phase motor with capapcitor
Hello I had problem with a vacuum compressor.the compressor is 220 V,single phase capacitor start motor.As soon as the motor is started the fuse is blowing.The motor is freely turning with hands.
When the terminal box of the motor opened I founf the capacitor is wire is broken.Is it the cause of fuse blowing.Please advise.The overload trip is not activating.The problem is of short circuiting.
Abdo Aug 19, 2010 9:35 AM
increasing starting torque
Dear sir;
How can i increase the starting torque of a 5HP single split phase capacitor start (500 microfarad) & capacitor run(60 microfarad) induction motor takin
Selvam Aug 17, 2010 5:17 AM
Capaciter Starter
Dear Sir,
The Capacitor Starter what difference from other Starter
praveen Aug 15, 2010 10:58 AM
power consumption
what will consumption of energy when supplied voltage is 410v and what will hen supplied voltage is 425v to same rating load
Nelson Aug 10, 2010 9:13 AM
Capacitor doubts
Dear Sir,
I m using 5Hp 3-phase Texmo motor against 7.5Hp ELGI double cyllinder compressor for agricultural use, I have designed a Capacitor with 75MFD, Motor s starting but stops within 2 mins, I have added more MFDs and increased the relay upto 14, But still not able to run continuously, Pls reply
LaurieK Jul 8, 2010 11:17 AM
start & end capacitors for flygt pump
How do I find the necessary components to start a Flygt pump: CP-3127.090-484 HT pumps rated @ 7.5hp, single phase?
a lady Jul 2, 2010 1:23 PM
brief definations
plz gv me brief explanation of all the 10 mentioned types of capacitor start motors(single voltage externally reversible type etc.)
manish pandey Jun 24, 2010 2:42 AM
motor capacitor
hi how can i calcilate the value of capacitor for using in my motor for increasing torque and efficiency of motor???
thanks
malik Jun 22, 2010 3:48 AM
capacitor run motor
Hi; During running why is the capacitor voltage greater than that of the main supply voltage.Thanks
wilmer Jun 21, 2010 6:02 AM
capacitor start motor
I have an induction power but i don't know the horse power of the capacitor.Then the question is how can i determine the horse power and the capacity of the capacitor?
Emmanuel Jun 19, 2010 9:54 AM
CSCR
hi, i would like to know more on capacitor start capacitor run motors especially when it comes to the principles of operation.
is it possible that i can give rate of the starting capacitor as 200 micro Farads then a running capacitor of 300microfarads on a 1.1 KW motor?
george Jun 13, 2010 10:38 PM
Capacitance and horsepower
how do i calculate for capacitane of a a CSCR motor. Again how do i convert horsepower to kilowatt
delwar Jun 12, 2010 1:53 AM
capacitor
Dear Sir,
I want to know that, how a capacitor size selected for a particular motor. Suppose, I want to start a 4 hp motor with capacitor, then what will be the size of the capacitor?
geethesh May 31, 2010 4:40 AM
1 phase submersible motors
pls send me the starter circuit diagram for capacitor start capacitor run 1.5 HP submersible motors
Hasan May 26, 2010 10:52 AM
Capacitor Design
Dear Sir,
I want to know that, how a capacitor size selected for a particular motor. Suppose, I want to start a 5 hp motor with capacitor, then what will be the size of the capacitor?
sridhar May 6, 2010 5:17 AM
RE: Learn about "Capacitor Start - Induction Run" Motors
thanks a lot sriram. u r explainations about induction motor was good it helped me to under... concept clearly thanks a lot
vishnu Apr 20, 2010 1:29 PM
split phase motor
if motor speed decreases why we chage capacitor
sanjeev Mar 15, 2010 3:39 AM
3d phase motor
explain 3d phase motor and it use ?
sriram balu Feb 21, 2010 9:29 AM
hi
All your requests will be handled in future articles. Do visit and add your comments.
Salitha Dec 2, 2009 9:36 PM
single phase induction motor
Please explain the phasor diagram of a single phase induction motor
vinod Nov 27, 2009 4:03 AM
sheded pole motor
how to increase the current or decrease or maintain constant for the change of fiux direction from unshaded region to sheded regeion?
Binesh Nov 26, 2009 12:59 AM
Two-speed with two-capacitor type
Can you please explain the Two-speed with two-capacitor type motor function
jawahar Nov 17, 2009 12:00 PM
capicitor start induction motor
How do we select the value of capacitor to be used in capicitor start induction motor?
elfatih elhadi morsal Sep 6, 2009 2:31 PM
split phase motor
how can I rewind adamaged winding meanly start/running winding
Puneet Sep 3, 2009 8:42 AM
Capacitor start motors
How to change the direction of rotation of the motor?
prasannavengataramana Aug 12, 2009 7:11 AM
capicitor start induction motor
we can see it in 3D visual
 
blog comments powered by Disqus